Wire size for 200 amp service copper

What size service entrance cable for 200 amp / residential serviceWhat size service entrance cable for 200 amp / residential service Amp 200 wire square copper service circuit wiring box electrical main panel breaker meter residential does pix need resets check200 amp service wiring diagram. Check Details. Meter wiring supplied …

Wire size for 200 amp service copper. Occupation. Electrician. Jul 7, 2020. #3. 4/0 AL is good for 180 amps. 250 AL is good for 205 amps. If you can show your calculated load is less than 180 amps, you can legally go up to the next standard size, a 200 amp breaker. That's code minimum. Over here, we would use 250 AL in a 2.5-3" depending on which size we felt like using.

Min. Wire Ampacity (100 ft away) = 125A × 1.2 = 150 Amps. That means that we need a wire with at least 150 ampacity to deliver 100 amp service 100 feet away. If you check the wire size chart (you have the link in the introduction), the #0 AWG wire (also known as 1/0 AWG wire) has 150 ampacity. That means that #0 AWG wire is the perfect size ...

250.66 is for the GEC not the neutral, however art. 250.24(C)(1) does reference that the grounded conductor not be smaller than the required GEC in Table 250.66. That being said unless you can calculate the neutral load and determine a #4 is satisfactory I would not do this. I generally downsize one wire size for the neutral.Apr 12, 2009 · Member. Join Date: Apr 2009. Posts: 11. Upvotes: 0. Received 0 Upvotes on 0 Posts. 2 conductor (s) per phase utilizing a 750 kcmil Copper conductor will limit the voltage drop to 2.81% or less when supplying 200 amps for 1000 feet on a 240 volt system. But that 750 copper is going to cost you. Copper gutter guards are a worthy investment, but how do you decide on the best ones? Our guide breaks down the best copper gutter guards to choose from. Expert Advice On Improving...For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch …Pre-Cut Length. The Southwire Company 250 ft. 4/0-4/0-4/0-2/0 AL SER Service Entry Electrical Cable is designed to be used as a panel feeder in multiple unit dwellings. This Cable can be used in wet or dry locations at temperatures up to 90˚C or 194˚F. Cable assembly and reinforcement tape jackets are made of sunlight-resistant, gray PVC.200 AMP ground wire size for 3 phase service. Three types of copper wire are required for a 200-amp electrical service: #2/0 AWG copper wire, #4/0 AWG aluminum, or copper-clad wire if it is run inside a three …Copper wire gauge sizes play a critical role in the performance and safety of electrical systems. Whether you’re setting up a new electrical circuit or replacing wires in an existi...

310.15 Ampacities for Conductors Rated 0–2000 Volts. (B) Tables. (7) 120/240-Volt, Single-Phase Dwelling Services and Feeders. For one-family dwellings and the individual dwelling units of two-family and multifamily dwellings, service and feeder conductors supplied by a single-phase, 120/240-volt system shall be permitted be sized …If you are looking to install a 200 amp service wire or breaker in your home, the minimum size of wire you will need is 4/0 awg copper wire, or 350 KCMIL if the wire length is over 100 feet. Using the wrong size wire, say 2/0 copper or 4/0 gauge aluminum wire, may cause circuit overload, tripping breakers, and electrical hazards.Applications: -SER cable is used as an above ground service entrance cable, a panel feeder and in branch circuits. The cable is rated at 600 volts and 90°C for use in wet and dry locations. SER cables are LEAD FREE and RoHS compliant. We stock Copper SER cable in a variety of gauge sizes for your electrical needs.In this case, the Amp Service Wire Size must be at least a 2/0 AWG of copper wire when installing a 200-amp panel. It’d help if you wired larger than a 4/0 AWG when using copper-clad or aluminum. Before determining if the 200 amps wire is best for you, think about a few things.Depending on the wire type, the best size for a 200 amp service is a 2 AWG copper wire or a 4 AWG aluminum or copper-clad aluminum wire. The size of the wires …

The minimum wire size is a 4/0 AWG 200 amp service aluminum wire or a 2/0 AWG copper. If we’re going to use an aluminum triplex cable for a single-phase setup, we will need a 4/0 AWG size neutral for 200 amp service, 2 4/0 AWG sizes for hot wires, and at least a 4-AWG bare copper wire for the ground.What size wire do I need for a 200 amp service? For a 200-amp service, you typically need copper wire sized at least 2/0 AWG (American Wire Gauge) or aluminum wire sized at least 4/0 AWG for the service entrance conductors. However, this can vary depending on local electrical codes and the length of the run, so consult a …According to the NEC, the wire size for 200 amp service is a 3/0 AWG copper wire or 4/0 AWG aluminum wire. You should increase wire size by 20% for every extra 100 feet run to account for voltage drop.In Table 250.66, it lists a 4 AWG copper grounding conductor for 2/0 copper or 4/0 aluminum service conductors, which are the sizes used for 200A services. However, in Table 250.122, it lists a 6 AWG copper grounding conductor for 200A service.

Places to eat in meadville pa.

200 Amp Wire = 200A × 100% / 80% = 250A Ampacity. That means that you can to use a wire that has an ampacity of 250A or higher in order to set up a 200 amp circuit. As you …The actual wire diameter of #14 copper wire can vary among manufacturers and wire types. The wire size table below gives the typical diameter of #14 copper wire as 0.073- .064 / 1.84-1.63 inches / mm. [Thanks to Anonymous for careful editing]Mar 29, 2024 · The National Electrical Code requires a minimum of 2/0 AWG for copper wire and 4/0 aluminum wire or copper-clad wire when installing a 200-amp panel. However, a licensed electrician should be the one to size the service cable due to a variety of factors that needs to be considered. The Quick Answer. Installing a 200 amp service requires a permit and professional experience. While you’ll need a qualified electrician, it’s good to know the basics ahead of time. For a 200 amp service, you’ll …

we just did a church that had a 200 and a 400 disconnect feeding 2 panels on the inside. the plans called for a 2/0 to building steel and a 2/0 to water pipe and a #6 to ground rod. the building was wood framed and incomming water was plastic. we placed 2 ground rods (1 at each disconnect) run a 2/0 to each disconnect from the ground rods and connected the ground rods together with 2/0 cadweldFor a 200 amp service, it’s recommended to use a #2/0 copper wire or #4/0 aluminum or copper-clad aluminum wire. Depending on the length of the wire run, you may need to …Wire sizes get larger as the gauge number gets lower, from 40-gauge all the way down to 0-gauge or 0.325 inches. Sizes larger than 0-gauge are listed as 00, 000 and so on. Wire with a low gauge will be harder to work with, and larger wire cutters may be necessary. AWG is measured differently for solid wire than it is stranded wire. What Size Grounding Wire is Required for a 200 Amp Service? A grounding wire ranging from 2AWG to 8 AWG is recommended for a 200-amp service. You can use 8AWG (Copper) or 6 AWG (Aluminum) grounding wires for a 200-amp service. You can also use copper conductors of 4AWG and aluminum conductors of 2AWG. How many breakers in a 200 amp panel; Wire size for 40 amps; Conclusion. To use a 200 amp service, you need #2/0 copper or #4/0 aluminum wiring. Contact an electrician for more information. Making sure you have the right wire size will ensure that your electrical equipment operates properly and does not cause a dangerous situation.1 AWG copper wire for 125 amp service. This wire has 130A ampacity; more than the minimum required 125A ampacity. 2/0 AWG aluminum wire for 125 amp service. This wire has 135A ampacity; more than the minimum required 125A ampacity. Note on 125 amp breaker wire size: For breakers, we use the 80% NEC rule. That means that a 125A breaker can only ...310.15 Ampacities for Conductors Rated 0–2000 Volts. (B) Tables. (7) 120/240-Volt, Single-Phase Dwelling Services and Feeders. For one-family dwellings and the individual dwelling units of two-family and multifamily dwellings, service and feeder conductors supplied by a single-phase, 120/240-volt system shall be permitted be sized …2/0 Gauge Wire Service Entrance Cables . Sort By. Sort By. Compare. Southwire 500-ft CONVERSE 2/0-2/0-1 Stranded Aluminum URD By-the-roll ... Compare 1-ft 2/0 Stranded Copper Tray By-the-foot. Find My Store. for pricing and availability. Compare ...Ampacity based on NEC ® Table 310.15 (B) (16) (formerly Table 310.16) Allowable Ampacities of Insulated Conductors Rated Up to and Including 2000 Volts, 60° through 90°C (140° through 194°F), Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F).

For a 200 amp breaker, the minimum recommended wire size is 2/0 AWG copper or 4/0 AWG aluminum. However, 3/0 AWG copper wire is a better option since it has higher maximum ampacity (200-225 amps). This ensures that the wire can safely handle the maximum current load of the breaker, without overheating or posing a fire risk. The Applications of ...

What Size Grounding Wire is Required for a 200 Amp Service? A grounding wire ranging from 2AWG to 8 AWG is recommended for a 200-amp service. You can use 8AWG (Copper) or 6 AWG (Aluminum) grounding wires for a 200-amp service. You can also use copper conductors of 4AWG and aluminum conductors of 2AWG.Application. Southwire® Type SE, Style SER service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to ...Each has a different ampacity for a specified gauge size, and these ampacities are found in NEC® Table 310.15(B)(16) for the calculations in this app. For example, 3/0 AWG copper has an ampacity of 200 amps at 75℃, while 3/0 AWG aluminum has an ampacity of 155 amps at 75℃. WIRE / CABLE TYPE:My house runs on 200 amp service. ... Increase the amps by 20% for 30-amp wire 100 feet away from the sub panel and 30% for 30-amp wire size 150 feet. ... Copper wire size Aluminum wire size; 50 feet: 10 AWG: 8 AWG: 75 feet: 8 AWG: 6 AWG: 100 feet: 6 AWG: 4 AWG: 200 feet: 4 AWG: 2 AWG: 250 feet:Allowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. 2/0 AWG copper wire is not completely out of the question, but its ampacity is 195 Amp-200 Amp, which will put it at a maximum load, so using 3/0 AWG copper is a better option. For grounding conductors, the minimum size for is 4 AWG ...4-gauge wire. 70 amps. 3-gauge wire. 85 amps. 2-gauge wire. 95 amps. These ratings are for standard copper NM sheathed cable, but there are instances where these amperage ratings vary. For example, there is aluminum wiring in some homes, and aluminum wires have their own ampacity-carrying capacity.The normal wire size for 100 amp service is 4AWG or 2 AWG for copper wiring and 2AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. These wire sizes can also used for direct burial. The 100 amp circuit for 240 volts can handle 24,000W of electricity.

Rheem furnace flame sensor.

Great china buffet el monte.

2/0-2/0-2/0-1 CU SERVICE ENTRANCE TYPE SER PVC JACKET 500 FT. Copper Service Entrance (SER) Cable. 2/0-2/0-2/0-1 CU SERVICE ENTRANCE TYPE SER PVC JACKET 500 FT. Southwire #: 27083501. Service Entrance Cable Style SER Service Entrance Cable, 600 Volt. Individual Conductors Rated XHHW-2. Jacket and Individual …For a 100 amp service, many electricians opt for wire size #2 or #1 AWG aluminum or copper-clad wiring. This is because aluminum conducts electricity slightly differently than copper. I know it can be a bit confusing, but the main takeaway for aluminum wire size is generally to go a size up (meaning a lower number on the gauge) … 1 AWG copper wire for 125 amp service. This wire has 130A ampacity; more than the minimum required 125A ampacity. 2/0 AWG aluminum wire for 125 amp service. This wire has 135A ampacity; more than the minimum required 125A ampacity. Note on 125 amp breaker wire size: For breakers, we use the 80% NEC rule. That means that a 125A breaker can only ... Allowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. 2/0 AWG copper wire is not completely out of the question, but its ampacity is 195 Amp-200 Amp, which will put it at a maximum load, so using 3/0 AWG copper is a better option. For grounding conductors, the minimum size for is 4 AWG ... Application. Southwire® Type SE, Style SER service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to ... 1 AWG copper wire for 125 amp service. This wire has 130A ampacity; more than the minimum required 125A ampacity. 2/0 AWG aluminum wire for 125 amp service. This wire has 135A ampacity; more than the minimum required 125A ampacity. Note on 125 amp breaker wire size: For breakers, we use the 80% NEC rule. That means that a 125A breaker can only ... The National Electrical Code requires a minimum of 2/0 AWG for copper wire and 4/0 aluminum wire or copper-clad wire when installing a 200-amp panel. However, a licensed electrician should be the one to size the service cable due to a variety of factors that needs to be considered.250.66(A) says the grounding electrode to a single or multiple rods shall not be required to be larger than a #6 copper wire. But in 250.66 it says for a 2/0 copper service entrance conductor, which you have for the 200 amp service, a #4 copper conductor. For residential I've always used a #4 because inspectors seemed to ask for it.Steps to Upgrade to a 200 Amp Service Wire. Ensure that power is off to the entire building, which may involve more than just shutting off the main breaker. Have utility company to disconnect electrical cables from the house. Remove the glass meter from the meter socket. Unscrew meter socket from side of house, then use cable cutters to sever ...When installing a 200 Amp service, you will need at least 3/0 AWG copper wire or 4/0 AWG aluminum or aluminum copper-clad wire. Allowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. ….

Wire sizes get larger as the gauge number gets lower, from 40-gauge all the way down to 0-gauge or 0.325 inches. Sizes larger than 0-gauge are listed as 00, 000 and so on. Wire with a low gauge will be harder to work with, and larger wire cutters may be necessary. AWG is measured differently for solid wire than it is stranded wire.I’m planning on upgrading my electrical service to 200 amps but I’m not sure what aluminum wire size I need. I get confused with the ambient temperature chart, I’m located around Houston Texas area. ... The 200 amp service can be derated to .83 so that's 166 amps. At 75 degrees C, 3/0 Al is 155 amps and 4/0 Al is good for 180 amps so …For a 100 AMP service, the recommended wire sizes are 4 AWG or 2 AWG for copper wiring and 2 AWG, 1 AWG, or 1/0 AWG for aluminum or copper-clad wiring. If the distance is more than 50 feet, it’s advisable to use #2 AWG copper wire. For underground service, you can install the wire inside a 1.25-inch PVC conduit, either Sch …Investor interest is on the rise and I have two price targets....ERO Ero Copper (ERO) is a copper producer with operations in Brazil and corporate headquarters in Vancouver, B.C. E...For a 100 amp sub panel, a minimum wire size of #3 AWG copper is recommended. This wire size can handle the current load without significant voltage drop. 2. Aluminum Wire: Aluminum wire is an alternative to copper wire and is often used in larger electrical applications. For a 100 amp sub panel, a minimum wire size of #1/0 AWG aluminum is ...On top of that, we will also calculate the 150 amp wire size for service 50 feet, 100 feet, 150 feet, 200 feet, and up to 500 feet away from the source. ... Case and point: Let’s express CM from the equation above and calculate it to determine the copper wire size for 240V 150 amp service 200 feet away with an allowable voltage drop of 3% ...For 150 amp, you will need a 1/0-size copper wir e size. For a 200 amp service, you will need a 250 kcmil-gauge copper wire size. For a 400 amp service, you will need a 600 kcmil-gauge copper wire size. For 600 amp, you will need a 1500 kcmil-gauge wir e size. We’ve got you covered if you want to buy a circuit breaker or a sub-panel.Generally, the ground wire size for a 200 amp service ranges from 2 AWG to 8 AWG. The best one is 2 AWG for copper wire and 4 AWG for aluminum or copper-clad aluminum wire. It is recommended to use them with 1.5-2.5 inches schedule 40 or 80 PVC conduit for underground service. It may differ depending on the materials, permission rules, codes, etc. Wire size for 200 amp service copper, The size of the ground wire for a 200-amp service depends on various factors, including local electrical codes and specific installation conditions. However, as a general guideline, a copper grounding conductor of 4/0 AWG (American Wire Gauge) or an aluminum conductor of 250 kcal is often recommended., Feb 4, 2024 · The appropriate size for a 60-amp breaker is between 6 AWG and 4 AWG (American Wire Gauge). As mentioned above, licensed electricians recommend using a wire size between 6 gauge and 4 gauge. You must increase the wire thickness if you intend to use aluminum wire. , On top of that, we will also calculate the 150 amp wire size for service 50 feet, 100 feet, 150 feet, 200 feet, and up to 500 feet away from the source. ... Case and point: Let’s express CM from the equation above and calculate it to determine the copper wire size for 240V 150 amp service 200 feet away with an allowable voltage drop of 3% ..., So we have to increase by twenty percent to get an accurate size for 200 amps at a distance. 200 Amp Wire for 100 ft away = 250A × 1.2 = 300A Ampacity. Ground Wire Minimum is #4, AWG Copper. The 200 amp service will have 4 AWG copper wires or 2 AWG aluminum wires operating from the ground electrode system to the main …, Size Wire for 100 Amp Service. AWG, American Wire Gauge, is the US standard for sizing electrical wiring. A 100 amp breaker panel requires either #4 copper wiring or #2 aluminum or copper-clad wiring. Which wire used is determined by the voltage drop and length of the wiring. The following table reflects wiring size, length, and voltage …, Jan 28, 2024 · How many breakers in a 200 amp panel; Wire size for 40 amps; Conclusion. To use a 200 amp service, you need #2/0 copper or #4/0 aluminum wiring. Contact an electrician for more information. Making sure you have the right wire size will ensure that your electrical equipment operates properly and does not cause a dangerous situation. , In the world of DIY projects, having the right tools and materials is essential. When it comes to electrical wiring, one important factor to consider is the gauge size of copper wi..., The size of the ground wire you need for a 200 amp service will depend on several factors, including the length of the wire run, the type of wire you are using, and the specific requirements of your local building code. In general, a 200 amp service will require a ground wire that is at least 2/0 copper or 4/0 aluminum or copper-clad aluminum ..., Allowable ampacity of 3/0 copper wire is 225 Amp, while the allowable ampacity of 4/0 aluminum wire is 205 Amp. 2/0 AWG copper wire is not completely out of the question, but its ampacity is 195 Amp-200 Amp, which will put it at a maximum load, so using 3/0 AWG copper is a better option. For grounding conductors, the minimum size …, 200 AMP ground wire size for 3 phase service. Three types of copper wire are required for a 200-amp electrical service: #2/0 AWG copper wire, #4/0 AWG aluminum, or copper-clad wire if it is run inside a three …, Single Family Residential Electrical Services | NFPA, The appropriate size for a 60-amp breaker is between 6 AWG and 4 AWG (American Wire Gauge). As mentioned above, licensed electricians recommend using a wire size between 6 gauge and 4 gauge. You must increase the wire thickness if you intend to use aluminum wire., A minimum of 4-gauge wire and 1 1/4-inch conduit is required for 100-amp service. Buildings that have gas heat may not need any more than 100-amp service. The service size of a bui..., Jun 11, 2020. #6. david luchini said: 3/0. (2/0 can't be protected at 200A.) My thought was that since the generator would not be supplying 100% of the loads in the house that the rating could be adjusted by the 83% of service rating per 310.15 (b) (7). F., The Quick Answer. Installing a 200 amp service requires a permit and professional experience. While you’ll need a qualified electrician, it’s good to know the basics ahead of time. For a 200 amp service, you’ll …, Advanced Wire Size Calculator. Enter the information below to calculate the appropriate wire size. Voltage - Enter the voltage at the source of the circuit. Single-phase voltages are usually 115V or 120V, while three-phase voltages are typically 208V, 230V or 480V. Amperes - Enter the maximum current in amps that will flow through the circuit., Choosing the right size wires for your sub panel is a matter of safety. It varies for several reasons, but you generally need 1 AWG copper wire for a 100 amp sub panel. Whether it be copper or aluminum, let’s take a look at what size wire you need for a 100 amp sub panel that’s 200 feet away. For amateur craftsmen, building a new structure ..., , What Size Grounding Wire is Required for a 200 Amp Service? A grounding wire ranging from 2AWG to 8 AWG is recommended for a 200-amp service. You can use 8AWG (Copper) or 6 AWG (Aluminum) grounding wires for a 200-amp service. You can also use copper conductors of 4AWG and aluminum conductors of 2AWG. , A 6-gauge copper wire is a standard for 50 amps. You can use a 4-gauge aluminum wire for 50 amps. If the wire length is 100 feet or above, you should consider a wire gauge, one level up, to prevent voltage drop—for instance, a 4-gauge copper wire for 50 amps at 100 feet. The NEC has also developed a wire gauge chart to help avoid …, 1 day ago · The calculator is designed to accept the total line voltage and current of the combined three cables. The equation for the area of a single wire is modified to: A = \frac {\sqrt 3 I \varrho L} {V} A =V 3 I ϱL. The factor of \sqrt 3 3 is needed to convert between the system's phase current and line current. The factor of 2 disappears, as there ... , Rewiring projects cost anywhere between $1,500 and $10,000 on average, depending on the complexity and the size of the rewiring. You can anticipate spending between $2 and $4 per square foot of wire, including labor and materials. Wire material ranges from $0.25 to $1.60 per linear foot., The correct wire size for different amp services depends on the specific application and the National Electrical Code’s guidelines. For example, a 100-amp service requires a minimum wire size of #2 copper or #1/0 aluminum, while a 200-amp service requires a minimum wire size of #2/0 copper or #4/0 aluminum., Calculating Wire/Cable Size formula for Three Phase Circuits. Wire Circular mils = √3 x 2 x ρ x I x L / (% Allowable Voltage drop of source voltage ) Where; Note: the Value of ρ = Specific resistance or resistivity of Conductor is used here for copper and aluminum is 11.2 and 17.4 respectively at 53° C (127° F), This article discusses poisoning from copper. This article discusses poisoning from copper. This article is for information only. DO NOT use it to treat or manage an actual poison ..., For a 200 amp service, the most commonly recommended size for copper wire is 3/0 AWG. This gauge ensures safe and efficient electrical distribution. Always adhere to local electrical codes and consult with an electrician. Copper Wire for 200 Amp Service Size Chart, The ordinary code of wire to use for a 200 amps service panel is #2/0 copper wire that needs to have a conduit of 2 inches. The electric code of your country may also set the bar for utmost safety. For aluminum or copper-clad wire, there shall be a wire with a gauge of #4/0 AWG. The MCM rating would be 211.60 kcmil., When it comes to electrical installations and appliances, safety should always be the top priority. One critical aspect of ensuring safety is choosing the right wire size for the a..., The minimum wire size is a 4/0 AWG 200 amp service aluminum wire or a 2/0 AWG copper. If we’re going to use an aluminum triplex cable for a single-phase setup, we will need a 4/0 AWG size neutral for 200 amp service, 2 4/0 AWG sizes for hot wires, and at least a 4-AWG bare copper wire for the ground., 1-48 of 225 results for "200 amp wire" Results. Check each product page for other buying options. Nassau Electrical Supply 200' Monmouth 4/0-4/0-4/0 Aluminum URD Triplex Cable. ... 50 FT Ground Wire 4 AWG Gauge Solid Bare Copper 200A Service Cables Electronic Stranded Wire Cable Electrics DIY. 5.0 out of 5 stars. 1. $113.72 $ 113. 72. FREE ..., Standard wire sizes for a 200-amp residential service could be as follows: 1. Copper Wire. 2/0 AWG (American Wire Gauge) copper is a standard size for a service entrance conductor (from the utility to the main distribution panel). You may need 3/0 or 4/0 AWG copper for the leading feeder conductors, which run from the main distribution …, 250.66 is for the GEC not the neutral, however art. 250.24(C)(1) does reference that the grounded conductor not be smaller than the required GEC in Table 250.66. That being said unless you can calculate the neutral load and determine a #4 is satisfactory I would not do this. I generally downsize one wire size for the neutral., 350 Amps. 350 kcmil Copper Wire. 500 kcmil Aluminum Wire. 400 Amps. 400 kcmil Copper Wire. 600 kcmil Aluminum Wire. This table is quite easy to use. For example, let’s say you are trying to figure out the feeder wire size for 300 amp service. By checking this table, you can see you will need either 4/0 AWG copper wire or 300 kcmil aluminum ...