Mcquay model number tonnage

McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment.

Mcquay model number tonnage. Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...

Enjoy the convenience of decoding multiple units simultaneously with our batch lookup tool. We are currently working on a model number decoder where we can bring you vital unit specifications based on model number. This information portal is put together by a few enthusiasts with the goal to remove friction for HVAC technicians and professionals.

Back-of-the-napkin business model is slang for a draft business model. Entrepreneurs sometimes jot down ideas on any available surface - including napkins. Slang for a draft busine...View and Download McQuay Vision CA Series installation and maintenance manual online. Vision CA Series air handlers pdf manual download. ... Air handler models oac/oah …McQuay Air-conditioning Limited offers a wide range of unitary products, including split systems, rooftop units, fan coils, air handling units and water source heat pumps. These products are designed to provide reliable and energy-efficient cooling and heating solutions for various applications. Visit our website to learn more about our unitary products and how they can meet your needs.The Condensing Unit for Applied Rooftop and Air Handler Systems. The McQuay RCS air cooled, remote condenser offers a wide selection of nominal capacities from 25 to 135 tons. Units are designed for quiet and energy efficient operation meeting ASHRAE 90.1 efficiency requirements. Dual circuits with scroll compressors from 25 to 105 tons with ...McQuay Water Chiller. Model ALR195C-X. Approximate capacity: 195 nominal tons using R-22 based on conditions of 95°F ambient air and a 10°TD change between 55°F and 45°F. Test pressure hi/lo: 380/150 psig. Max relief pressure: 450 psig. (4) 8-cylinder compressors, 60 Hp each 460V 60 Hz 3 phase. (14), 26 in. dia. fans and motors: 1hp, 460V ...GROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD …Summary of Contents for McQuay AGZXXXBS Series. Page 1 Installation, Operation and Maintenance Manual IOMM AGZ-5 Group: Chiller Part Number: 330411801 Effective: October 2004 Supercedes: IOMM AGZ-4 Air-Cooled Scroll Compressor Chiller AGZ 026B through 130B 60 Hertz, R-22...

GROUP mcQUAY..P&Af'EX Inc. t36001ndustriaiParkB!vd.P.O.Box1551,Minneapolis,Mn.55440 . ND ... Available in three model types for horizontal and vertical unit arrangements: LSL VERTICAL UNIT ... -----NUMBER OF FANS IN STANDARD UNIT LYF-VENTILATING FAN SECTION LHD -HEATING AND VENTILATING UNITIn 2009 we added McQuay Water Source Heat Pump units to our product line. We handle Horizontal, Vertical, and Console units up to 72000 BTU. Over 40 years ago McQuay introduced a complete line of water source heat pumps. WSHP units are used in schools, hospitals, office buildings, hotels, and many other applications.View and Download McQuay MWH011B manual online. Horizontal Water Source Heat Pumps And Cooling Only Unit. MWH011B heat pump pdf manual download. ... Heat Pump MODEL MWH030BR MWH040BR MWH050BR MWH060BR MWH070BR 13.2 14.6 18.5 22.4 NOMINAL COOLING CAPACITY Btu/h 29920 44870 49880 63160 76460 15.1 16.6 20.0 22.4 NOMINAL HEATING CAPACITY Btu/h ...Enjoy the convenience of decoding multiple units simultaneously with our batch lookup tool. We are currently working on a model number decoder where we can bring you vital unit specifications based on model number. This information portal is put together by a few enthusiasts with the goal to remove friction for HVAC technicians and professionals.MCQUAY MODEL NUMBER LOOKUP - SOSTENESCAVALCANTE.COM.BR. Large selection of McQuay parts. mcquay model number description 2_| Documentine.com Model number on the back cover: A1456, A1507, A1516, A1529, A1532. ... FIND TONNAGE ON AHU NOMENCLATURE QUALITY HVAC INFO 101 ...Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons.

A three-speed control switch with off position and wall plate is furnished for installation by the contractor in a standard 2 x 4-inch junction box. The speed switch can be wired to any three of the four motor taps to provide air delivery in three increments from 100% to 50% of rated airflow. Air discharge.Kohler toilets have one-piece and two-piece models. When you need to replace a part, you’ll need the Kohler toilet model number. Model numbers are four digits long sometimes preced...Do not open more than five full turns. 3. Replace external key "E" and securely tighten setscrews "B" over key and setscrews "C" into keyway in fixed half of the sheave. 4. Put on belts and adjust belt tension to 4 lbs. -0.7 lbs. (18N -3N) for a 1⁄2" to 3⁄4" (13 mm to 19 mm) belt deflec-tion height. 5.Chiller Details. 1998 McQuay Air Cooled Liquid Chiller. Model: ALS125AS27. Rated capacity: 125 tons. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 460 V, 274 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL155QA10DA and SAL155QA10DA, 380/460 V, 461/489 LRA.Air Distributors Company, Inc. 913 Ulrich Ave Louisville, KY 40219 800-866-1210

Minnesota pigs for sale.

consistent with the McQuay rooftop line. Expanded flexibility along with the availability of the state-of-the-art, MicroTech direct digital control (DDC) system on the RDS 800C and 802C makes the RDS unit the ideal selection in rooftop air handlers. Lower installation costs The McQuay RoofPak air handling unit arrives on the job site Detailed model information for the MCQUAY 40 Ton Water Cooled Chiller. Find Industrial and Mechanical Equipment and salvage on Texas Used Chillers. ... Model Number: WGZ040CW27-ER10; Serial Number: STNU080200191; Year: 2008; 40 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-410A;Lot 163 at ESS Industrial Equipment Auction; Ends October 20 (NO RESERVE!!!) from ESS - RBI Equipment Sales & Surplus.Overview. Positive pressure design with R-134a refrigerant which has no ozone depletion potential and no phase- out schedule. Smallest footprint per ton in the industry to optimize equipment room space. The exclusive movable diffuser geometry design avoids the potential for a surge. Quiet compressor design with unique refrigerant injection ...Figure 1: Magnetic Bearing Compressor Shaft. system replaces conventional oil lubricated bearings and a direct drive motor eliminates the need for a lubricated gear box. The compressor shaft, shown in Figure 1, levitates on a magnetic cushion and is the compressor’s only major moving component.

Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.Through your Carrier model number, you can determine your AC tonnage. You can do so in three simple steps. Step 1: Seek the Carrier model number. As discussed, you can find this information on several parts of our AC, depending on the type. Step 2: Search online for sites that contain related information.Tesla delivered a record-breaking 241,300 electric vehicles in the third quarter, blowing past expectations as other U.S. automakers experienced a drop in sales as the result of a ...Do not open more than five full turns. 3. Replace external key "E" and securely tighten setscrews "B" over key and setscrews "C" into keyway in fixed half of the sheave. 4. Put on belts and adjust belt tension to 4 lbs. -0.7 lbs. (18N -3N) for a 1⁄2" to 3⁄4" (13 mm to 19 mm) belt deflec-tion height. 5.Compressor Stage 1. Cooling Capacity 56000. Family Comfort. Gas Stages 1-Stage. Nominal Seer 16. Refrigerant R410A. Tonnage 5. Voltage (Phase) 208/230 V 1-Phase. Air Flow Vertical. a solution for your specific application. Contact your local McQuay sales office for computer selections of chillers to match your requirements. The following chart provides recommendations for the model choice for your application. Application McQuay Model Cooling, most hours at full load WSC – Single compressor chiller Part Number: 668996503. Date: November 2011. IM 930-3 ©2011 McQuay International ® Page 2 of 32 / IM 930-3. Model Nomenclature Vertical Floor Unit (Size *007 - 070) NOTE: For illustration purposes only. Not all options available with all models. Please consult McQuay Sales Representative for specific availability.McQuay chillers m# PEH079 S# 5YC0100700 style 0547362010 m# PEH076 S# 5ZA81012-01 style 9566323018 trane screw centravac m# RTHA130FCMONDUC3LF2LFNN00GUQ S# U90K03031 device# 3036RT130 appreciate it building engineer would like something more than a shoot from the hip nominal tonnage.Find the model number. Within this string of letters and numerals, you should find an even, two-digit number. The capacity in tons of a Trane outdoor unit can be determined by dividing the 7th and 8th digit of the model number by 12. So if the model number is #4TTX4036A1000AA, take 36 and divide by 12, equaling 3 tons.The Magnitude® centrifugal chiller delivers energy savings that building owners demand. Using direct drive technology, integral variable-frequency drives, and R-134a, R-513A, R-515B, or R-1233zd (E) refrigerant, Magnitude® is up to 40% more efficient than standard centrifugal chillers and can save up to $4 million over the life of the chiller.Apr 8, 2019 · Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one for a 2 ton system. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from the building or process directly to the outdoor air using refrigerant to air coils and fans that blow outdoor air directly over those coils. A water cooled chiller rejects the absorbed heat to an additional fluid loop that can ...

Manufacturer McQuay. Tonnage 50. Air or Water Air Cooled. Refrigerant R-410A. Voltage 208. Phase 3. Hz 60. Model Number AGZ050EDSEMUG00. Serial Number STNU190100221.

Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.2000 McQuay Air Cooled Chiller-350 Tons. Model: ALS370BS-27ER10. S/N: STNU000600277. Refrigerant R-22, max pressure 300 psi. Power supply 460V, 60Hz, 3phase. (24) Condenser fans, 2.0 HP motor, 28 in. dia.1140 rpm, 60 Hz. High efficiency fin and tube type condensers with integral sub cooler, (12) fins per in. and 4 rowsMcQuay International offers a complete range of condensing units from 12 to 120 tons (42 to 420 kW). This manual covers Model ALP 027C through ALP 041C condensing units with capacities from 25 to 40 tons (88 to 140 kW). See Product Manual ALP1-2 for information on Models ALP 012D through ALP 019D,Daikin Industries, Ltd. is a leading innovator and provider of advanced, high-quality air conditioning solutions for residential, commercial, and industrial applications.SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200Page 1 Installation, Operation, IOM 1210-1 and Maintenance Manual Group: Chiller Part Number: IOM1210-1 Date: August 2014 Magnitude ® Magnetic Bearing Centrifugal Chillers Model WMC, C Vintage 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz...; Page 2: Table Of Contents ©2014 Daikin Applied. Illustrations and data cover the Daikin Applied product at the time of publication and ...Replacement parts can be obtained by contacting McQuay at 1-800-37-PARTS. When contacting McQuay for service or replacement parts, refer to the model number and serial num-ber of the unit as stamped on the nameplate attached to the unit. IMPORTANT The United States Environmental Protection Agency (EPA) regulations cover introduction and disposal ofThis Used MCQUAY 50 Ton Water Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment. ... Model Number: WGZ050AW27-ER10; Serial Number: STNU071100075; Year: 2007; 50 Tons Nominal Cooling; 460V/3Ph/60Hz; Refrigerant: R-22; Scroll Compressors;Chillers. At LEL International, we ensure that you have access to a wide variety of new and used industrial chillers for sale, allowing you to find the one that best meets your needs. Our HVAC chillers can provide the appropriate temperature, humidity, and ventilation for structures of any size or nature. Whether you are seeking heat management ...• Because of the simple design of the McQuay condensing unit, installation is quick, simple, and very little maintenance is required. Note: For further information on a complete air-cooled split system, refer to Catalog 580 (Destiny Indoor Air Handlers). Agency Listed Nomenclature Note: For larger size units (greater than 20 ton), refer to

Sams gas price daytona.

Is lisa salters gay.

AGZ 035A Installation, Operation And Maintenance Manual. 100 pages. AGR 070AS Operation Manual. 53 pages. WMC-B 145S Installation Manual. 100 pages. 5ACV 30 CR Installation Manual. 68 pages. AGZ 010BS Installation, Operation And Maintenance Manual.This number can range from 18 to 60. To determine the tonnage of your AC unit, divide this two-digit number by 12. '12' represents 12,000 BTU/hr or one tonnage of cooling capacity. Refer below for the corresponding tonnage based on the number and BTU information: 18 = 1.5 tons. 24 = 2 tons.McQuay ALS250AS27-ER10 I need the manual and service literature, thanks!! Reply . 10-01-2013, 06:54 PM #2. freonrick. View Profile View Forum Posts ... The model number is AGS351DP27NN-ER10, the compressors are HSA205QY13YA, thanks!! Reply . Quick Navigation Chillers Open Forum Top. Site Areas; Settings; Private Messages;Most efficient full load and part load operation, up to COP 3.6. New generation screw compressor with high operation efficiency. Largest capacity air-cooled screw chiller, up to 450 tons. Small footprint to optimize space and reduce installation costs. Quietest operation with sound pressure levels as low as 76 dBA with no attenuation.McQuay Hong Kong; Worldwide Locations; Serving You with Commitment; Certifications; PRODUCT. Applied Products; Unitary Products; Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongSALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200McQuay 6- to 10-ton horizontal units have a common cabi-net size and common water, condensate, and duct connection locations for easier and more efficient installation. The cabinet is constructed of unpainted, G-60 galvanized steel. Large panels provide access to the fan/motor compart-ment and the compressor/control compartment. The interiors ofYou can find the Trane tonnage and SEER in the 5 th, 7 th and 8 th characters of the Trane model number. The 5 th character represents SEER in a single number; the 7 th and 8 th characters, also numbers, show the tonnage code.. The Trane model number nomenclature for central air conditioners and heat pumps is explained below in this Trane model lookup.MCQUAY® HVAC age. How to determine the date of production/manufacture or age of McQuay® HVAC Systems. The date of production/manufacture or age of McQuay® HVAC equipment can be determined from the serial number or MFG. DATE located on the data plate.These links wiIl lead to yóu purchase a próduct from another cómpany. Mcquay Chiller Model Numbers Serial Numbers And How Question Posted By Francisco the Building Engineer on May 3, 2011 Refer to the manufacturers website for their HVAC nomenclature of the model number and serial numbers and how those numbers …Depending on which Whirlpool appliance, the model number can be easily found on the inside surface of the appliance. The model numbers are generally found inside the drawer or on t... ….

McQuay Hong Kong; Worldwide Locations; Serving You with Commitment; Certifications; PRODUCT. Applied Products; Unitary Products; Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong KongThe sump includes the pump, motor, heater and lubricant/vapor separator system. The lubricant is pumped through the external oil cooler and then to the oil filter located inside the compressor housing. WSC/WDC/WCC 063-126 units, single or dual compressor, all utilize a water-cooled oil cooler for each compressor.A ton of air conditioning equals 12,000 BTU, and 36 divided by 12 equals 3, so the data plate below indicates the system is 3 tons. Here's a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 - 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 4 tons.Often used in conjunction with coils in air handlers, chillers receive warm fluid from the air handler coil or process load, lower the temperature of the fluid, then a pump returns the fluid to the air handler coil or process. Chillers come in two main varieties: air-cooled and water-cooled. An air cooled chiller rejects the heat absorbed from ...Replacement parts can be obtained by contacting McQuay at 1-800-37-PARTS. When contacting McQuay for service or replacement parts, refer to the model number and serial num-ber of the unit as stamped on the nameplate attached to the unit. IMPORTANT The United States Environmental Protection Agency (EPA) regulations cover introduction and disposal ofInstall a tee fitting with a leak-tight removable cap in each tube near the sensor fitting. This facilitates connecting a manometer or pressure gauge if testing is required. Use different colored tubing for the duct pressure (HI) and reference pressure (LO) taps, or tag the tubes. McQuay recommends 1/8" ID tubing.Simply divide the BTUs by 12,000 to calculate the tonnage of your unit. For example, if your air conditioner is 36,000 BTUs, you have a 3-ton unit. Some manufacturers bury tonnage or BTU information in their model numbers. Look for an even, two-digit number between 18 and 60. How old is my heat pump? How do I read my carrier heat pump serial ...Available from 300 to 1200 tons, single compressor centrifugal chillers offer excellent full-load and part-load performance for increased energy savings and an excellent life cycle return on your investment. Using R-134a or R513A refrigerant, these chillers easily integrate with building automation systems, are seismic compliant, quiet and have ...Model AGZ 030C through AGZ 190C Two-Circuit Chiller (4-Fan Model Illustrated) Cover Picture: Model AGZ 180C, nominal 180-ton capacity, shown with optional coil louvers installed. “W” Shaped Coil High Efficiency Service Headroom Canted Fan Deck Improved Efficiency Reduced Recirculation 4 or 6 Scroll Compressors Mcquay model number tonnage, Find Us. McQuay Air-conditioning Limited (+852) 2893 6261; Unit 901~905, 9/F,Elite Centre, 22 Hung To Road, Kwun Tong, Kowloon,Hong Kong , SALES. [email protected]. 817-229-3171. North Texas Office: Dan @ 817-966-5350. South Texas Office: Mike @ 210-413-3333. This Used McQuay 50 Ton Air Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment., Model Number: AM000013. Description Reviews (0) * McQuay * 60 Ton System * Water Cooled * Model WGZ060AW27-ERIO * Full Controls * Year of Mfg. 2002 * Approximate Foot Print: 9' x 4' x 5' Reviews There are no reviews yet. Be the first to review "Chiller - 60 Ton McQuay 2002" Cancel reply. You must be logged in to post a review., Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1. Cooling efficiency. H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only) G ..., 1996 McQuay Air Cooled Screw Chiller 200 Ton. Model: ALS204A27. Rated at 204 tons using R-22. (2) McQuay Screw Compressor model no.'s: SAL175RA13DA. McQuay Chiller Barrel Model no. E 2010. Refrigeration side MAWP: 225 psi @ 109°F, MDMT: 20°F at 225 psi. ... Model: ALS204A27; Serial Number: 56F8139401; Chiller Details. Air Cooled or Liquid ..., HVAC units are identified by their multiple-character model number that identifies a particular type of unit. Below you will find a partial explanation of the alphanumeric identification code (aka Model Number Nomenclature). Our samples have been simplified to concentrate more on the location of each individual units tonnage and air flow ..., Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter., (2 to 5 Ton) Bulletin #490034 ... CHA16H-261 model requires 2 per unit, LB-82199CH (47J25). CHA16-413 model requires 2 per unit, LB-82199CF (47J23). CHA16-513-653 models require 3 per unit, LB-82199CG (47J24). Correct number of guards are furnished per order number. Compressor Crankcase Heater (Optional for CHA16H-261 Model ..., Model WDC, Dual Compressor, 160 to 2700 Tons (560 to 9500 kW) ... The chart below illustrates the relative IPLV efficiencies of various McQuay options for a 500 ton selection. The chiller cost increases as the efficiency improves. Industry Leading Efficiencies (kW/Ton) .6.5.4.3 WSC WDC WDC w/VFDWSC w/VFD.505.403.365, Look for the 7th and 8th digits, or maybe 8th and 9th digits, of the model number. It will be a number divisible by 6 or 12, and represents the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons., The first way to calculate tonnage is to just multiply the number of square feet of your room by 0.0016. This will give you AC tonnage value in no time. Suppose you are going to buy an air conditioner for 600 sq ft area, you can calculate AC tonnage by: AC Tonnage = (Area of Room in Square Feets) * 0.0016 tons/sq ft., Daikin Industries, Ltd. is a leading innovator and provider of advanced, high-quality air conditioning solutions for residential, commercial, and industrial applications., Model MPS. Daikin Maverick II commercial packaged rooftop systems, from 15 to 75 tons, use ozone-friendly R-410A refrigerant and are designed for new, retrofit or replacement applications on one to three-story buildings like offices, schools, libraries, and strip malls. Arriving as a complete packaged solution, Maverick II maximizes your design ..., Whether you need to make a warranty claim or find replacement parts, there are plenty of reasons why you may need to find the model number for your GE motor. Here are several helpf..., All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ pensive jobsite coordination and field mounting of motors has been eliminated .. Motor life is increased with the McQuay air handling units, Daikin McQuay Model PDAE Product Nomenclature. Note: For Illustration purposes only. Not all options available with all models. Unit Type. P = PTAC. Product Identifier. PDAE = A/C PMES/EA Replacement. Design Series. 1 = A Design 1 2 = B Design 2 3 = C Design 3 4 = D Design 4 5 = E Design 5. Unit Size. 007 = 7,000 009 = 9,000 012 = 12,000 015 ..., That would be a 50ton Roof Top Unit or RTU. It has DX cooling, that is Direct Expansion or simply the Refrigerant cools the air, opposed to a CW unit that has Chilled Water to cool the air. Reply. 07-31-2012, 06:26 AM #5. beenthere., WHERE’S MY MODEL NUMBER? All appliances have a model number and a serial number tag located on the appliance. Generally they are available for the customer to find quickly. ... You're reviewing: 055371705 Daikin-McQuay ALP027C CKT 1 Condenser Coil Your Rating. Quality. 1 star 2 stars 3 stars 4 stars 5 stars. Nickname. Summary. Review. …, Download 140 McQuay Air Handlers PDF manuals. User manuals, McQuay Air Handlers Operating guides and Service manuals., Additional Product Details. McQuay & Snyder. McQuay Air Cooled Water Chiller- 220 Ton. Model ALS220A, S/N 56K8146201. (2) Compressors. Refrigerant: R 22. Overall dimensions: 356 in. L x 84 in. W x 95 in. H., be seen that a Model MC216 UI1it will deliver 6550 CFM with a fan outlet velocity of 1605 FPM and that the cooling coil face velocity will be 500 FPM. 2. From the General Specifications Table on Page 11 it is found that the maximum number of zones is 12 for a Model MC216 unit. Each available zone in a McQuay Multi-Zone unit, Cover pictures: Upper unit: Model WSC 087, 500 ton single compressor chiller with factory-mounted starter Lower unit: Model WDC 126, 2000 ton, dual compressor chiller , Manufactured in an ISO Certified Facility. ... Cutaway view of McQuay Model CE 063 Compressor, Nominal 250 Tons, Overview. Positive pressure design with R-134a refrigerant which has no ozone depletion potential and no phase- out schedule. Smallest footprint per ton in the industry to optimize equipment room space. The exclusive movable diffuser geometry design avoids the potential for a surge. Quiet compressor design with unique refrigerant injection ... , That would be a 50ton Roof Top Unit or RTU. It has DX cooling, that is Direct Expansion or simply the Refrigerant cools the air, opposed to a CW unit that has Chilled Water to cool the air. Reply. 07-31-2012, 06:26 AM #5. beenthere., Daikin McQuay Packaged System Nominal capacity 006 = 6 tons 007 = 7.5 tons 010 = 10 tons 012 = 12 tons Design vintage A = Vintage 1. Cooling efficiency. H = High (exceeds ASHRAE 90.1) Line voltage 2 = 208 volt power supply 3 = 230 volt power supply 4 = 460 volt power supply 5 = 575 volt power supply Heat medium Y = None (cooling only) G ..., Air Handlers. Subcategory. Air Handlers. View All. Used McQuay approximately 15 - 20 Ton, 2000 to 6000 CFM. model RDS708BY air conditioning unit. Overall Dimensions 68" wide x 52" high. 5 HP Evaporator fan motor. All loads 460 volt. S/N FB0402030023603. Stock#20667., The model number decoder and serial number decoder for all major brands. ... For example, if you have the model number 24ACC636ABB3 from Carrier. That will include all units from 1.5 ton to 5 ton based on the cooling capacity. This will also include all SEER rating from 14 to 21 SEER. ... McQuay: Chiller : 7: PTAC09C208F3C-M: McQuay: …, Catalog 1108- McQuay Efinity Horizontal Water Source Heat Pumps Page 3 of 76. Enfinity Horizontal Ceiling Water Source Heat Pumps Sizes 007-070 (1/2 to 6 Tons) ModelWCCH(StandardRange:55°Fto110°F) Model WCCW(GeothermalRange:30°Fto110°F) McQuay Enfinity Horizontal Ceiling units are designed for use in multiple floor apartments, office ..., Daikin Applied RoofPak® RPS (15-140 Tons) Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak® applied rooftop systems the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, with capacities from 15 to 150 tons, they combine the lower ... , 16" × 44" Flat Top Replacement Unit - Model PDAE/PDHE Unit Sizes 007 - 017 • R-410A Refrigerant ... In 2008 McQuay is proud to continue our tradition of design excellence with the introduction of our highly efficient and quiet 16 × 44 Applied PTAC/ PTHP. Type EA (1970), ALP 012D through 019D. IM 687. Install the unit with three feet of side clearance for air entrance to the coil and for servicing. Provide four feet of service access at each end to access the evaporator, compressors, electrical control panel and piping components. Do not allow debris to accumulate near the unit., Manufacturer McQuay. Tonnage 50. Air or Water Air Cooled. Refrigerant R-410A. Voltage 208. Phase 3. Hz 60. Model Number AGZ050EDSEMUG00. Serial Number STNU190100221., Engineered HVAC Solutions for Alaska - Stinebaugh & Company